F219Fault · ThermalUsually repairable
Indramat DKC F219: Motor Overtemp. Shutdown
What F219 means
The motor's temperature has gone above its shutdown limit.
Symptoms
Fault after heavy running, or at once if the sensor circuit is open.
Is it repairable?
Yes: sensor and winding repairs on MKD and MHD motors.
Common causes
- Motor overloaded
- Motor cooling poor
- Faulty temperature sensor or wiring
Safe checks
- 1Feel whether the motor is hot
- 2Check the temperature sensor wiring with power off
Drives hold dangerous voltage after power-off. Checks should only be done by qualified personnel, with power isolated and the DC link discharged.
Reviewed by AutomIQ repair technicians. Code and name from the ECODRIVE DKC and ECODRIVE03 diagnostic descriptions.
Related Indramat DKC faults
- F218Amplifier overtemp. shutdown
- F226Undervoltage in power section
- F281Mains fault
- F822Encoder 1 failure: signal too small
- F860Overcurrent: short in power stage
- F878Velocity loop error